عیب یاب التراسونیک بتن CJ-10

عیب یاب التراسونیک بتن CJ-10


بررسی اجمالی محصول

عیب یاب التراسونیک بتن CJ-10

 

نقد و بررسی : عیب یاب التراسونیک بتن CJ-10

عیب یاب التراسونیک بتن CJ-10

دستگاه عیب یاب آلتراسونیک بتن

 

                              عیب یاب التراسونیک بتن CJ-10

  • Purpose

☆ Testing of building foundation piles by cross-hole sonic logging;

☆ Inspection of concrete defects by ultrasonic method,

   such as uncompacted ,cellular, hole area.

☆ Detecting defects of one hole by one trigger two receive.

☆ Testing dynam performance of geotechnical

   investigation、rock、concrete etc.

  • Specification

☆ Technology code for testing of building foundation piles JGJ 106 —2003

☆ Technical Specification of Dynamic Pile Tests for Highway Engineering JTG/TF81-01-2004

☆ Technology specification for inspection of concrete defects by ultrasonic method CECS 21:  2000

☆ Technical specification for geotechnical investigation method GB50021—2001

  • Performance

☆ High efficient testing. Lifting speed is more than 60m/s.( 20 cm distance )。

☆ Display the test data graphically. User can watch analyze result directly;

☆ Fast and precise Automatic judge the sound parameters. Real-time wave display to assure test efficiency;

☆ Humanized software design. Software design apply to User and construction plant. its help information ensure user handle easily;

☆ Linking the rebound apparatus directly. Detecting strength of concrete by ultrasonic-rebound combine method with linking rebound apparatus directly,and get strength of concrete in time. The functions apply for national patent.

☆ Being sensitive to receiving signal. Can receive signal more than 10m in concrete without defects

Can supply smooth power for radial energy transducer needless external power.

Standard USB storage with big capacity.

☆ Interior lithium battery supply power for apparatus work more than 6 hours.

☆ Portable, small, light apparatus (1.75Kg).

☆ Extending function for testing thickness of concrete by impacting echo method.

☆ Professional and powerful analysis software on windows system. It can export the data to  Excel or word for advanced analysis

  • Technical Data

عیب یاب التراسونیک بتن CJ-10

 

 Item specifications Item specifications
Main Control Unit high-performance Embed Computer Display  640×480High brightness TFT  Panel
Input Keyboard storage 1G(Internal)+2G(U-Disk
interface USB
Receive Channel One Max Sample Data length 64k
Trigger Mode Continuous Trigger、

External Trigger

Trigger Voltage(V) 65、125、250、500、1000 selectable
Receive sensitivity ≤30μv Amplifier gain 82dB
Amplifier bandwidth 5KHz~500 kHz Sample Periods 0.05μs~6.4μs,8 grades electable
Sound time accuracy 0.05μs Amplifier resolution 0.39%
Power Interior lithium battery,work more than 6 hours Size 260 mm×185 mm×60 mm
External lithium battery,work more than 6 hours(select Weight 1.75 kg(include lithium battery)
DC 12V Temperature -10℃—+40℃
AC 100V~240V、50/60Hz
  • Configure
Instrument Signal Cable Plane energy transducer U-Disk
 
Box staff box lithium battery(selectable)  
 