نقد و بررسی : عیب یاب التراسونیک بتن CJ-10
عیب یاب التراسونیک بتن CJ-10
عیب یاب التراسونیک بتن CJ-10
- Purpose
☆ Testing of building foundation piles by cross-hole sonic logging;
☆ Inspection of concrete defects by ultrasonic method,
such as uncompacted ,cellular, hole area.
☆ Detecting defects of one hole by one trigger two receive.
☆ Testing dynam performance of geotechnical
investigation、rock、concrete etc.
- Specification
☆ Technology code for testing of building foundation piles JGJ 106 —2003
☆ Technical Specification of Dynamic Pile Tests for Highway Engineering JTG/TF81-01-2004
☆ Technology specification for inspection of concrete defects by ultrasonic method CECS 21: 2000
☆ Technical specification for geotechnical investigation method GB50021—2001
- Performance
☆ High efficient testing. Lifting speed is more than 60m/s.( 20 cm distance )。
☆ Display the test data graphically. User can watch analyze result directly;
☆ Fast and precise Automatic judge the sound parameters. Real-time wave display to assure test efficiency;
☆ Humanized software design. Software design apply to User and construction plant. its help information ensure user handle easily;
☆ Linking the rebound apparatus directly. Detecting strength of concrete by ultrasonic-rebound combine method with linking rebound apparatus directly,and get strength of concrete in time. The functions apply for national patent.
☆ Being sensitive to receiving signal. Can receive signal more than 10m in concrete without defects
☆ Can supply smooth power for radial energy transducer needless external power.
☆ Standard USB storage with big capacity.
☆ Interior lithium battery supply power for apparatus work more than 6 hours.
☆ Portable, small, light apparatus (1.75Kg).
☆ Extending function for testing thickness of concrete by impacting echo method.
☆ Professional and powerful analysis software on windows system. It can export the data to Excel or word for advanced analysis
- Technical Data
عیب یاب التراسونیک بتن CJ-10
Item | specifications | Item | specifications |
Main Control Unit | high-performance Embed Computer | Display | 640×480High brightness TFT Panel |
Input | Keyboard | storage | 1G(Internal)+2G(U-Disk |
interface | USB | ||
Receive Channel | One | Max Sample Data length | 64k |
Trigger Mode | Continuous Trigger、 External Trigger | Trigger Voltage(V) | 65、125、250、500、1000 selectable |
Receive sensitivity | ≤30μv | Amplifier gain | 82dB |
Amplifier bandwidth | 5KHz~500 kHz | Sample Periods | 0.05μs~6.4μs,8 grades electable |
Sound time accuracy | 0.05μs | Amplifier resolution | 0.39% |
Power | Interior lithium battery,work more than 6 hours | Size | 260 mm×185 mm×60 mm |
External lithium battery,work more than 6 hours(select | Weight | 1.75 kg(include lithium battery) | |
DC 12V | Temperature | -10℃—+40℃ | |
AC 100V~240V、50/60Hz |
- Configure
Instrument | Signal Cable | Plane energy transducer | U-Disk |
Box staff | box | lithium battery(selectable) | |